In the previous part, we examined which implant shape is best suited for different bone densities and the intended use of cortical and cancellous implants. In this section, we will continue to explore the rationale behind implant selection through clinical case studies. We will also touch on the physics and biological processes involved in implant placement.
Series: Thread, Taper, and Reverse Taper: How Implant Shape Determines Its Application → Part 1. Choosing an implant by bone density → Part 2. Clinical application of different implant shapes (you are here)
Let’s start with cortical implants. More precisely, with so-called supercortical implants. We already know that the stability of such implants is determined by the contact of the implant neck (collar) with the cortical layer. The implant design shown below is intended for the most common bone types, D2–D3. It necessarily includes microthreads on the implant neck to reduce pressure and trauma in the densest layer of bone.
The thinner the cortex, the more tapered the implant neck should be. However, the ability to retain an implant in the cortex is limited. When there is almost no cortex (bone density between D3 and D4), the implant can only be retained in cancellous bone. In this case, cancellous implants with a wide, aggressive thread profile are required, but we will discuss these later.
For D1 bone, where the cortical bone is almost continuous, a different design is used with shallow threads and a smooth, tapered implant body. However, again, much depends on the clinical case and the implant placement method.
The table below shows the design variations of cortical implants only.
As we mentioned in the first part of this article, there are no perfect implants, but it is possible to choose the perfect one for a specific clinical case. Therefore, even when working with approximately the same bone type, it is possible to choose implants with different designs and purposes.
The picture below shows an ideal D1 bone scenario, for which a simple-shaped implant with a reverse taper in the implant neck area would be suitable.
For such clinical cases, implants with a simple profile and a tapered neck are the ideal choice; see examples below.
As seen in the illustration above, the implants are very similar in shape. The key differences are in the thread profile: a single, very shallow thread profile in the specialized implant for dense bone (left) and a double-lead thread with a variable profile in the XGate implant, plus microthreads on the implant neck.
Both options are suitable for:
Additionally, the narrowing of the neck (reverse taper) reduces the pressure in the densest part of the cortical bone, minimizing the risk of overload and compression necrosis.
The second advantage is that it is much easier to achieve dual platform switching on this type of implant; see the illustration below.
Another important point is that the price of implants with this design is among the most affordable. This doesn’t mean they are inferior to more expensive ones; with the right choice, the survival rate is among the highest. It is simply a mass-produced product utilizing proven technology, so each unit is inexpensive while boasting high manufacturing precision and a clean, porous surface.
These are designed for soft bone with little cortical bone. Primary stability is achieved through friction between the threads and the cancellous bone.
Here too, there are several varieties and transitional forms. Some are interesting, some are more exotic, but most clinical cases can be resolved with standard solutions.
Here are the most interesting designs of cancellous implants:
Let’s briefly discuss whether it is possible to use one type of implant in different bone types. Yes, it is possible. However, as discussed in detail in Part 1, using cortical implants in loose bone will result in relatively low torque and poor primary stability. This is acceptable for a delayed loading protocol, but the time for complete osseointegration increases significantly (on average, +2 months).
Conversely, placing a cancellous implant in D1 bone will be very challenging. If the osteotomy is prepared according to the standard protocol to fit the implant diameter, the implant may become stuck. If the socket is over-widened, the implant will only be held in place by the very tips of the threads, leaving large voids between the implant body and the socket walls. Given that dense bone is already poorly vascularized, bone growth will be slow, increasing the risk of fibrous integration rather than osseointegration.
In D2 and transitional D2-D3 bone, placing a purely cancellous implant will present fewer challenges, although insertion will be physically more demanding due to torque resistance.
There are two ways to solve this problem:
The following photo shows a restoration 9 years post-op, and the bone level around the implants has remained virtually unchanged. Several factors were at play here:
Conversely, there are examples of poor implant selection. The image shows cortical conical implants designed for a ridge-splitting protocol. They were placed in dense bone, but due to excessive pressure at the implant neck, significant bone volume was lost even before the healing abutments were placed. Now they need to be removed, the implant site remodeled, and new implants placed.
Another example in the image below shows significant bone loss due to incorrect implant design. This is a mandible, and at the time of implant placement, the cortex was distinct and fairly thick. Implants with a microthreaded neck designed for cortical bone anchorage should have been used—perhaps the previously discussed reverse-taper implants. In that case, the cortical bone would not have been damaged and would have been preserved in sufficient volume.
Let’s look at the rules and specifics of implant placement during immediate implantation protocols. The implant shape is crucial here. For example, in the position of the central or lateral incisors, the implant bed is quite narrow. The illustration below shows a tapered-cylindrical implant with a flat apex. If the implant had a pronounced conical shape during placement, there would be a risk of slipping toward the vestibular wall. However, this implant fits neatly and tightly into the prepared bed almost immediately, achieving high-quality apical anchorage.
Recall anatomy: the walls of the socket after tooth extraction are also cortical bone. Therefore, if the tip of the implant is embedded 4–5 mm into dense bone, in most cases, this provides sufficient primary stability for immediate provisionalization.
The double-lead thread and a domed apex of the XGate implant also perform well in the immediate implantation protocol, in both the anterior and posterior regions.
The following picture shows implantation into the socket of a multi-rooted tooth, specifically into the interradicular septum. As seen in the right picture, taken several months later, the implantation was more than successful.
Here is another clinical case where differentiated selection of implants allowed the patient to have implants and restorations placed on the same day.
The initial clinical situation is complex, with moderate bone atrophy in the upper jaw, and the bone is of very low density: D3 in the anterior region and D4 in the posterior regions. The old restorations rested on the roots of natural teeth, which had become damaged and needed to be removed. The patient experienced discomfort and pain.
In these circumstances, a delayed protocol with a removable denture placed during the healing period is typically recommended for the upper jaw. The lower jaw is in better condition, making immediate implantation with immediate loading an option. However, the patient’s request was clear: to leave with “teeth” on the day of implantation.
This would not have been possible without the concept of cortical and cancellous implants.
The images below show the implants placed according to the above-mentioned scheme. In the upper jaw, 10 cancellous implants were placed, 8 of which are used to support the temporary prosthesis. The 2 distal implants were placed with insufficient torque and were not loaded. In the lower jaw, 8 implants were placed, 6 of which are used to support the temporary prosthesis for the same reason.
After three months, osseointegration was successfully completed, secondary stability was sufficient for the placement of a permanent restoration, and here is the result.
The result isn’t perfect; as you can see from the image, there were issues with one bridge—it didn’t seat properly on the distal abutment. This isn’t a major issue. The bridge segmentation concept worked to its advantage here, too. The doctor removed the problematic bridge, trimmed one crown, and then performed a single-tooth restoration on that implant.
If the restoration had been done as a continuous full-arch splint, the entire prosthesis would have had to be removed due to a problem with one crown. But with this approach, one bridge was removed, modified, or remade, while the patient could use the other side of the jaw.
As a result, the patient is happy and can eat any food with virtually no restrictions.
Here’s what the situation looks like five years later. The prosthesis is fine, but there is still some work to do on the soft tissue, and some gum grafting is needed. But that’s a topic for another article.
To be fair, I should note that there are a few issues with the dental lab work. The bridges are well-made but not perfect. However, these are typical, functional restorations, not exhibition pieces. Furthermore, the cost of these restorations is not exorbitant.
All of the above arguments confirm that a practicing clinician should have more than one implant system or design in their arsenal. There should always be a choice for a wide variety of clinical situations.
Here’s another clinical example. The patient also expressed a desire to leave after the surgery with her teeth intact. The initial clinical picture was quite dire.
In this case, we’ll only briefly present the results. The point is that the same principle was adopted here: cancellous implants for the upper jaw and cortical implants for the lower jaw.
That’s all for now. In the next section, we’ll discuss the rules for using short implants and which implants to choose to avoid sinus lift surgery. All of this will also be based on clinical examples. Stay tuned for our next publications.
Previous: ← Part 1. Choosing an implant by bone density
Get the complete case study and explore our product catalog.
We hope you found this clinical case interesting. If you have any questions about the characteristics and delivery of XGATE Dental products, please contact us in any convenient way.
Falkensteiner Straße 77, 60322 Frankfurt am Main Germany
350 W Passaic St (3rd floor), Rochelle Park, NJ 07662 USA
Clinical cases and articles published on this website are intended for dental professionals and are provided for informational and educational purposes only. They describe the individual experience of the treating clinician and do not constitute medical advice, a treatment recommendation, or a guarantee of outcome. Results depend on patient anatomy, clinical indication, and the technique applied.
XGATE Dental products must be used in accordance with the current Instructions for Use. Product availability and regulatory clearance vary by country; not all products shown are available in every market. Third-party trademarks and implant system names are used solely to indicate dimensional compatibility and remain the property of their respective owners. XGATE Dental is not affiliated with, endorsed by, or sponsored by these manufacturers.
Create a free account to save it
Already have an account? Log in
Product List Saved
You can view all saved Product Lists in your Personal Account