XGATE Dental
Specialization: Multi-Unit Abutment systems, dental implants, and digital prosthetic solutions
Headquarters: Frankfurt am Main, Germany
In the previous part, we discussed the indications and contraindications for each retention type and examined detailed methods to mitigate the disadvantages and limitations of cement retention. This article will analyze the features of screw retention and address its potential challenges.
We will begin by examining less ideal applications before moving to more reliable and durable approaches.
Series: Cement or Screw Retention for Implant Prosthetics → Part 1. Retention options, advantages and disadvantages → Part 2. Screw retention: features and how to choose a method (you are here)
Let’s revisit the issue of errors in prosthesis framework fabrication and deviations during installation. Similar to construction, a small error at the foundation (e.g., 5-10 mm) can magnify significantly at higher levels, resulting in deviations of 30-40 cm for a 3-4 story building, or 1.4-1.7 meters for a 10-15 story building.
While prosthetic deviations aren’t typically this large, even a small angular error of 2-5° during fabrication can lead to noticeable gaps at the implant-abutment or abutment-prosthesis interface. These gaps not only create pathways for microflora penetration and biofilm formation but also allow for micromovement of the structure. This can lead to screw loosening (best-case scenario) or even component or implant fracture (worst-case scenario).
The following illustration and table (previously shown in Part 1) demonstrate this point. The picture clearly shows the difference between screw retention directly to an implant (left) and screw retention to a multi-unit abutment (MUA) (right). We see two designs with approximately the same angular deviation from the planned position. A significant difference is visible in the resulting deviation at the occlusal aspect of the structure, stemming from the difference in the lever arm height.
With direct-to-implant retention, the abutment component acts as a long lever arm, measured from the implant platform. This lever arm height is typically 9-15 mm. Furthermore, a long abutment component seated with a gap creates leverage that continuously stresses the implant neck and the retaining screw. This increases the risk of screw loosening or fracture, abutment damage, or even implant failure.
On the other hand, the same angular misfit when attaching the framework to an MUA results in a much smaller deviation at the top of the restoration because the lever arm is shorter (measured from the MUA platform). Moreover, the MUA itself should seat fully and passively onto the implant. Therefore, any risk of screw loosening or fracture primarily concerns the prosthetic screw connecting the frame to the MUA, not the abutment screw holding the MUA to the implant. The likelihood of damaging the MUA itself is minimal, and the risk of implant complications due to superstructure misfit is significantly reduced.
The table below illustrates that the longer the lever arm, the greater the final deviation from the planned position for a given angular misfit. These data confirm the advantages of using MUAs compared to direct screw retention onto implants. The average effective lever arm height for a direct screw-retained restoration (crown + abutment component) is often around 15 mm; with an angular misfit of 5°, we get a clinically significant deviation of 1.3 mm at the occlusal aspect. Whereas with a shorter lever arm height of 5 mm (typical above an MUA platform), the same 5° misfit results in a more acceptable deviation of only 0.43 mm. The restorative platform height of many standard MUAs is around 3.5-5.5 mm, but low-profile options like the XGate V-type MUA feature a height of only 1.5 mm, further reducing the lever arm effect. Therefore, a restoration with an effective lever arm of 5 mm above the MUA platform is common for screw retention on MUAs.
Compounding the issue, an angular misfit of 2° is virtually impossible to detect visually during restoration placement. Yet, the resulting gaps and micromovement can lead to significant complications.
Consider another example where the screw-retained crown fails to seat completely. Let’s analyze the reason.
The implant axis is not ideally centered relative to the planned crown contour, and the adjacent natural tooth (#45) is mesially tilted. On the distal side (contact with tooth #47), the contact aligns with the restoration’s path of insertion. However, on the mesial side (contact with tooth #45), the tilted adjacent tooth creates an interference. This mesial contact prevents the restoration from fully seating along its intended path of insertion. The illustration highlights this interference.
We could adjust (grind) the proximal contact on the crown, allowing it to seat, but this would create an open contact between the prosthesis and tooth #45, which is undesirable (leading to food impaction). Alternatively, the adjacent tooth could be orthodontically uprighted or restored to achieve parallel contacts, but this involves treating other teeth.
For single crowns, direct-to-implant screw retention is a common approach. While compromises may be necessary in such single-unit cases (like careful adjustment), for multiple-unit restorations (bridges), MUAs are strongly recommended to manage such issues more predictably. Failure to use MUAs in multi-unit situations with challenging paths of insertion or minor inaccuracies can lead to problems illustrated in the radiographs below. In both images, we can see gaps between the abutment components and the implant platforms, indicating a lack of passive fit.
In these examples, the implants are installed relatively parallel, with an angular deviation between them of only 3-4°. Despite this slight deviation, the direct screw-retained abutments do not seat passively. The situation might be exacerbated by the internal hex connection type; a conical connection is often considered more forgiving of minor angular misfits compared to flat-to-flat hex connections.
Some clinicians might proceed with definitive placement despite a poor fit. The restoration might function for a period, but the eventual outcome is often component failure, as shown below.
With such a misfit, the screws bear excessive occlusal load instead of it being distributed between the screws and a precisely fitting connection interface. Under dynamic and multidirectional masticatory forces, the screws are prone to loosening or fracture. Fortunately, in this instance, the screws failed first (acting like a mechanical fuse), preserving the implants. Note the plaque accumulation on the screws, a consequence of the large gaps at the implant-abutment interface.
Plaque and deposits also accumulate at the interface itself. Such contamination can lead to peri-implant mucositis or peri-implantitis. It’s worth noting that some bacterial ingress occurs even with well-fitting components due to the inherent microgap at any implant-abutment interface. Bacterial dimensions allow penetration into this space.
However, the volume of microbial contamination differs significantly. With a passive fit, biofilm is typically minimal, and any odor is usually slight and only noticeable upon removal. Conversely, with a poorly fitting prosthesis, significant biofilm accumulation can cause noticeable malodor. In any case, screw retention offers the advantage of retrievability, allowing removal for professional cleaning and maintenance of the prosthesis and underlying tissues. Patients should be encouraged to attend regular recall appointments (at least annually) for examination and professional hygiene.
Consider another crew retention example. The image shows significant inclination of both the implants and adjacent teeth. The restoration was seated, albeit with difficulty, achieving minimal visible gaps at the interface.
However, achieving this apparent fit came at the cost of inducing internal stress within the system. This indicates significant stress on the components and surrounding bone. This results in non-physiological, constant lateral loading of the peri-implant bone, even without occlusal function. The consequences, in the form of significant crestal bone loss around the implant, are clearly visible on the radiograph.
Consider another clinical situation with difficulties fitting a single restoration. The posterior molar has tilted mesially into the long-standing edentulous space. The proximal surfaces are clearly not parallel.
To achieve seating, the crown’s mesial proximal contact was modified by creating a concavity.
Now let’s explain what the problem is here. Normal contact between teeth allows the teeth to move relative to each other. And it is good when the tooth moves:
Implant-supported restorations are immobile, but proper point contacts allow adjacent natural teeth to maintain their physiologic mobility relative to the fixed restoration.
In this case, the broad, concave contact area effectively splints the premolar to the immobile implant restoration, restricting its natural movement. This lack of physiologic stimulation can lead to PDL disuse atrophy. Paradoxically, the tooth might eventually become mobile, an open contact may develop, and in severe cases, the natural tooth could be compromised or lost over time, even though initially it might seem supported.
Let’s sum up the intermediate results.
Implant failure necessitates removal, potentially grafting, and a completely new surgical and restorative cycle.
This allowed the restoration to seat vertically but compromised the connection’s integrity. Note the left implant: the modified abutment interface barely engages the implant connection, essentially ‘hanging’ on the screw. The screw bears the entire load, as the stabilizing features of the interface are lost. Even if the screw holds temporarily, the large gap will accumulate debris and biofilm, leading to malodor and inflammation. Furthermore, micromovement of the improperly seated abutment transmits non-axial forces to the implant, increasing the risk of screw loosening, crestal bone loss, and potentially implant loosening over time. Eventually, the patient may present with a failed restoration or even a failed implant.
The cases described above can lead to a negative attitude towards screw retention. Actually this is not true. Here are the main scenarios for using screw retention, in which the likelihood of complications is minimal:
Of course, this is an attempt to correct the surgeon’s mistakes or cases where installing implants in parallel and in positions where there used to be natural teeth is impossible, but only screw retention can partially correct the situation.
While tightening the framework with a screw might eliminate the visible gap in such cases, it can introduce undesirable tension. The framework would then function like a stressed bowstring. This can lead to bone resorption or screw fracture. Therefore, a restoration failing the Sheffield test should be remade.
Barring specific contraindications, both screw-retained and cement-retained restorations can be successful in many situations. However, some general guidelines can aid in selecting the appropriate retention method.
Consider screw retention when:
Consider cement retention when:
There’s the controversial topic of implants with significant deviations from the arch form. Multi-unit abutments offer a standard, cost-effective solution for managing deviations with screw retention. Alternatively, custom abutments can correct for any reasonable deviation when using cement retention. Custom abutments entail higher expense, making it an individual decision.
We hope this information proves useful in your practice. Stay tuned for our next publications.
Previous: ← Part 1. Retention options, advantages and disadvantages
Get the complete case study and explore our product catalog.
We hope you found this clinical case interesting. If you have any questions about the characteristics and delivery of XGATE Dental products, please contact us in any convenient way.
Falkensteiner Straße 77, 60322 Frankfurt am Main Germany
350 W Passaic St (3rd floor), Rochelle Park, NJ 07662 USA
Clinical cases and articles published on this website are intended for dental professionals and are provided for informational and educational purposes only. They describe the individual experience of the treating clinician and do not constitute medical advice, a treatment recommendation, or a guarantee of outcome. Results depend on patient anatomy, clinical indication, and the technique applied.
XGATE Dental products must be used in accordance with the current Instructions for Use. Product availability and regulatory clearance vary by country; not all products shown are available in every market. Third-party trademarks and implant system names are used solely to indicate dimensional compatibility and remain the property of their respective owners. XGATE Dental is not affiliated with, endorsed by, or sponsored by these manufacturers.
Create a free account to save it
Already have an account? Log in
Product List Saved
You can view all saved Product Lists in your Personal Account